Type 02.1.02.002.01
Technical data
Type of actuation | direct control | |
Nominal size | 2 mm | |
Pump connection P | hose Ø 6 mm | |
Working connection A | external thread R 1/8˝ | |
Ventilation connection R | internal thread M5 | |
Function | normally closed NC* | |
Operating pressure | max. vacuum 99,9 % up to 2 bar | |
Ambient temperature | max. 80° C | |
Duty cycle ED | 100 % | |
Enclosure protection in compliance with DIN 40050 |
IP 00 IP 65 with connector (Art.-No. 229/000002) |
|
Power consumption |
||
24 V/DC | 10 W | |
24 V/AC and 230 V/AC | 8,5 VA | |
Current consumption |
||
24 V/DC | 0,417 A | |
24 V/AC | 0,354 A | |
230 V/AC | 0,039 A | |
Standard voltages |
||
24 V/DC | Art.-No. 261/002011 | |
24 V/AC | Art.-No. 261/002012 | |
230 V/AC | Art.-No. 261/002015 |
Other voltages available on inquiry
*Function „normally open“ NO P=R