Type 02.2.01.050.01

Technical data
Type of actuation       vacuum pilot control
Nominal size       50 mm
Pump connection P       internal thread R 2˝
Working connection A       internal thread R 2˝
Ventilation connection R       internal thread R 1 1/4˝
Function       normally closed NC
Operating pressure       max. vacuum 99,9 %
Ambient temperature       max. 80° C
Duty cycle ED       100 %
Enclosure protection in
compliance with DIN 40050
      IP 00
IP 65 with connector
(Art.-No. 229/000002)

Power consumption
24 V/DC       10 W
24 V/AC and 230 V/AC       8,5 VA

Current consumption
24 V/DC       0,417 A
24 V/AC       0,354 A
230 V/AC       0,039 A

Standard voltages
24 V/DC       Art.-No. 263/050011
24 V/AC       Art.-No. 263/050012
230 V/AC       Art.-No. 263/050015

Other voltages available on inquiry