{"id":1027,"date":"2025-07-10T17:25:24","date_gmt":"2025-07-10T15:25:24","guid":{"rendered":"http:\/\/wordpress-messnervakuum.p372769.webspaceconfig.de\/?p=1027"},"modified":"2025-09-03T16:01:50","modified_gmt":"2025-09-03T14:01:50","slug":"type-02-2-01-032-15","status":"publish","type":"post","link":"https:\/\/www.messner-vakuumtechnik.de\/en\/2025\/07\/10\/type-02-2-01-032-15\/","title":{"rendered":"Type 02.2.01.032.15"},"content":{"rendered":"<section class=\"l-section wpb_row height_medium\"><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_1-2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image align_none\"><div class=\"w-image-h\"><img decoding=\"async\" width=\"929\" height=\"1024\" src=\"https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/09\/Type-02.2.01.032.15-929x1024.jpg\" class=\"attachment-large size-large\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/09\/Type-02.2.01.032.15-929x1024.jpg 929w, https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/09\/Type-02.2.01.032.15-272x300.jpg 272w, https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/09\/Type-02.2.01.032.15.jpg 1286w\" sizes=\"auto, (max-width: 929px) 100vw, 929px\" \/><\/div><\/div><div class=\"w-separator size_small\"><\/div><div class=\"w-image align_none\"><div class=\"w-image-h\"><img decoding=\"async\" width=\"444\" height=\"11\" src=\"https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/07\/balken-orange.png\" class=\"attachment-large size-large\" alt=\"\" loading=\"lazy\" srcset=\"https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/07\/balken-orange.png 444w, https:\/\/www.messner-vakuumtechnik.de\/wp-content\/uploads\/2025\/07\/balken-orange-300x7.png 300w\" sizes=\"auto, (max-width: 444px) 100vw, 444px\" \/><\/div><\/div><div class=\"w-btn-wrapper align_justify\"><a class=\"w-btn us-btn-style_1\" href=\"\/wp-content\/uploads\/2025\/09\/Type-02.2.01.032.15_GB.pdf\"><span class=\"w-btn-label\">Datenblatt<\/span><\/a><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h1 class=\"sppb-addon-title\">Type 02.2.01.032.15<\/h1>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<th style=\"background-color: #f7f7f7;\" colspan=\"2\">Technical data<\/th>\n<\/tr>\n<tr>\n<td>Type of actuation<\/td>\n<td>vacuum pilot control<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>Nominal size<\/td>\n<td>32 mm<\/td>\n<\/tr>\n<tr>\n<td>Pump connection P<\/td>\n<td>internal thread R 1 1\/4\u02dd<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>Working connection A<\/td>\n<td>internal thread R 1 1\/4\u02dd<\/td>\n<\/tr>\n<tr>\n<td>Ventilation connection R<\/td>\n<td>internal thread R 3\/4\u02dd<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>Function<\/td>\n<td>normally closed NC<\/td>\n<\/tr>\n<tr>\n<td>Operating pressure<\/td>\n<td>max. vacuum 99.9 %<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>Ambient temperature<\/td>\n<td>max. 80\u00b0 C<\/td>\n<\/tr>\n<tr>\n<td>Duty cycle ED<\/td>\n<td>100 %<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>Enclosure protection in compliance with DIN 40050<\/td>\n<td>IP 00<br \/>\nIP 65 with connector (Art.-No. 229\/000002)<\/td>\n<\/tr>\n<tr style=\"background-color: #f7f7f7;\">\n<th colspan=\"2\">Power consumption<\/th>\n<\/tr>\n<tr>\n<td>24 V\/DC<\/td>\n<td>10 W<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>24 V\/AC and 230 V\/AC<\/td>\n<td>8.5 VA<\/td>\n<\/tr>\n<tr style=\"background-color: #f7f7f7;\">\n<th colspan=\"2\">Current consumption<\/th>\n<\/tr>\n<tr>\n<td>24 V\/DC<\/td>\n<td>0.417 A<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>24 V\/AC<\/td>\n<td>0.354 A<\/td>\n<\/tr>\n<tr>\n<td>230 V\/AC<\/td>\n<td>0.039 A<\/td>\n<\/tr>\n<tr style=\"background-color: #f7f7f7;\">\n<th colspan=\"2\">Standard voltages<\/th>\n<\/tr>\n<tr>\n<td>24 V\/DC<\/td>\n<td>Art.-No. 263\/032151<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td>24 V\/AC<\/td>\n<td>Art.-No. 263\/032152<\/td>\n<\/tr>\n<tr>\n<td>230 V\/AC<\/td>\n<td>Art.-No. 263\/032155<\/td>\n<\/tr>\n<tr style=\"background-color: #eceded;\">\n<td colspan=\"2\">Other voltages available on inquiry<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/section>\n","protected":false},"excerpt":{"rendered":"DatenblattType 02.2.01.032.15 Technical data Type of actuation vacuum pilot control Nominal size 32 mm Pump connection P internal thread R 1 1\/4\u02dd Working connection A internal thread R 1 1\/4\u02dd Ventilation connection R internal thread R 3\/4\u02dd Function normally closed NC Operating pressure max. vacuum 99.9 % Ambient temperature max. 80\u00b0 C Duty cycle ED...","protected":false},"author":1,"featured_media":1342,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[],"class_list":["post-1027","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-3-2-way-solenoid-valves"],"_links":{"self":[{"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/posts\/1027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/comments?post=1027"}],"version-history":[{"count":3,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/posts\/1027\/revisions"}],"predecessor-version":[{"id":1030,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/posts\/1027\/revisions\/1030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/media\/1342"}],"wp:attachment":[{"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/media?parent=1027"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/categories?post=1027"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.messner-vakuumtechnik.de\/en\/wp-json\/wp\/v2\/tags?post=1027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}