Type 02.1.01.002.01
| Technical data | |
|---|---|
| Type of actuation | direct control |
| Nominal size | 2 mm |
| Pump connection P | hose Ø 6 mm |
| Working connection A | hose Ø 6 mm |
| Ventilation connection R | internal thread M5 |
| Function | normally closed NC* |
| Operating pressure | max. vacuum 99.9 % up to 2 bar |
| Ambient temperature | max. 80° C |
| Duty cycle ED | 100 % |
| Enclosure protection in compliance with DIN 40050 | IP 00 IP 65 with connector (Art.-No. 229/000002) |
| Power consumption | |
| 24 V/DC | 10 W |
| 24 V/AC and 230 V/AC | 8.5 VA |
| Current consumption | |
| 24 V/DC | 0.417 A |
| 24 V/AC | 0.354 A |
| 230 V/AC | 0.039 A |
| Standard voltages | |
| 24 V/DC | Art.-No. 260/002011 |
| 24 V/AC | Art.-No. 260/002012 |
| 230 V/AC | Art.-No. 260/002015 |
| Other voltages available on inquiry | |
| *Function “normally open” NO P = R also available | |