Type 05.2.02.025.01

Technical data
Type of actuation vacuum pilot control
Nominal size 25 mm
Pump connection P hose Ø 27 mm
Working connection A internal thread R 1˝
Ventilation connection R internal thread R 1/2˝
Connection 1 internal thread R 1/4˝
Connection 2 soft ventilation hose Ø 6 mm
Function normally closed NC
Operating pressure max. vacuum 99.9 %
Ambient temperature max. 80° C
Duty cycle ED 100 %
Enclosure protection in compliance with DIN 40050 IP 00
IP 65 with connector (Art.-No. 229/000002)
Power consumption (per coil)
24 V/DC 10 W
24 V/AC and 230 V/AC 8.5 VA
Current consumption (per coil)
24 V/DC 0.417 A
24 V/AC 0.354 A
230 V/AC 0.039 A
Standard voltages
24 V/DC Art.-No. 284/025011
24 V/AC Art.-No. 284/025012
230 V/AC Art.-No. 284/025015
Other voltages available on inquiry
Type 05.2.01.020.04
Type 05.2.01.032.17